SMHcoders FZ LLC · Abu Dhabi · Industrial software +971 52 991 9203Sales@SMHcoders.com
Products/08/ComGate
Lab-qualifiedIntegration & commissioning

Find the mapping error in the lab, not on the skid.

One bench where devices, tags and protocols are engineered, exercised against a simulator and watched at the wire level — with the test evidence captured, not screenshotted.

COMGATE · 08Lab-qualified
Objective

Remove the integration guesswork before commissioning.

ProtocolsModbus TCP · UDP · RTU
OPCUA · DA bridge
ModesServer · client · simulator
Runs onWindows
01/ LiveInteractive · runs in your browser

A Modbus server, live in your browser.

This is the traffic monitor. A client polls holding registers 40001–40010 once a second; every request and response is decoded at the frame level. Use the write console to push a value — it is an FC06 frame, encoded exactly as on the wire.

  • Real Modbus TCP framing: MBAP header + PDU
  • FC03 polls, FC06 writes, exception on a bad address
  • Simulated in the page — nothing leaves your browser
02/ CapabilitiesIntegration & commissioning
01
Engineering workflow

Projects, devices and tag maps, importable from the metering-skid spreadsheets integrators already use.

02
Simulator and slave modes

Run as a Modbus server with patterned data, or connect as a client to a live device.

03
Traffic monitor

Protocol-level visibility of every poll and write, with a write console for manual test cases.

04
Historian, trends and reports

Captured test evidence rather than a screenshot in a notebook.

05
Qualification evidence

Exercised against third-party Modbus masters and simulators and an OPC explorer, with the results recorded.

06
Honest about coverage

Modbus TCP and the OPC DA bridge are qualified end to end. RTU is flagged in the tool itself as not yet field-qualified.

03/ Workflow

The pre-FAT test chain

Integration risk retired in three steps, each producing its own capture. Nothing is signed off on the strength of a demo.

Step 01Local simulator

Client polling a Modbus slave on localhost — status healthy.

Step 02OPC DA + UA

DA bridge browsed, UA endpoint exposed on the same project.

Step 03Physical board

Holding registers read back over Modbus TCP.

04/ EvidenceFrom the delivery record
727
OPC items browsed

Imported straight into the project as tags.

367
Writable items

The write path proven, not just the read path.

6
Data types mapped

Across 4 Modbus object types.

5
Protocols

Modbus TCP, UDP, RTU · OPC UA, DA.

Proof of concept · your data

See it on your plant.